Preliminary W49F020
- 8 -
Command Codes for Product Identification and Boot Block Lockout Detection
BYTE
SEQUENCE
ALTERNATE PRODUCT (6)
IDENTIFICATION/BOOT BLOCK
LOCKOUT DETECTION ENTRY
ADDRESS
SOFTWARE PRODUCT
IDENTIFICATION/BOOT BLOCK LOCKOUT
DETECTION EXIT (7)
ADDRESS
DATA
DATA
1 Write
5555
AA
5555H
AAH
2 Write
3 Write
2AAA
5555
55
90
2AAAH
5555H
55H
F0H
Pause 10
μ
S
Pause 10
μ
S
Software Product Identification and Boot Block Lockout Detection Acquisition Flow
Product
Identification
Entry (1)
Load data 55
to
address 2AAA
Load data 90
to
address 5555
Pause 10 S
Product
Identification
and Boot Block
Lockout Detection
Mode (3)
Read address = 00000
data = DA
Read address = 00001
data =8C
Read address = 00002
data in DQ0 = "1"/"0"
(4)
Product
Identification Exit(7)
Load data 55
to
address 2AAA
Load data F0
to
address 5555
Normal Mode
(5)
(2)
(2)
Load data AA
to
address 5555
Load data AA
to
address 5555
Pause 10 S
Notes for software product identification/boot block lockout detection:
(1) Data Format: DQ7
DQ0 (Hex); Address Format: A14
A0 (Hex)
(2) A1
A17 = V
IL
; manufacture code is read for A0 = V
IL
; device code is read for A0 = V
IH
.
(3) The device does not remain in identification and boot block lockout detection mode if power down.
(4) If the output data in DQ0= " 1," the boot block programming lockout feature is activated; if the output data in DQ0= " 0," the lockout feature is
inactivated and the block can be programmed.
(5) The device returns to standard operation mode.
(6) Optional 1-word cycle (write F0 hex at XXXX address) can be used to exit the product identification/boot block lockout detection.