M61528FP
Rev.1.1, Dec.17.2003, page 10 of 30
Quality factor : 0.4 / 0.6 / 0.8 / 1.0 (Gv=+8dB, f0=10KHz setting)
Power on Reset
This IC builds in the power on reset function.
The voltage of VCC (24 pin) less than 5.0V, the serial DATA can not accept.
5.0V
V
(V)
(S)
Reset time
Release of reset.
After reset is canceled, the serial DATA can accept.
Relationship Between Data and Clock
The DATA signals are read at rising edges of the CLOCK.
The LATCH signal “H”
D0
D1
D2
D3
D13
D14
D15
The LATCH condition
“L”
“H”
“L”
“H”
How to transmit DATA.
This IC reads DATA signal at the rising edge of the CLOCK.
When DATA are transmitted, setting up the DATA line is always “L” when the falling edge of the CLOCK.